Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ABSTRACT


26 septiembre 2013

AMERICAN JOURNAL OF NEURORADIOLOGY. Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device

K. Yavuz, S. Geyik, I. Saatci and H.S. Cekirge

Background and Purpose: The Pipeline Embolization Device was reported to be safe and effective in the treatment of sidewall aneurysms, preserving the patency of the vessels covered by the construct. However, to date, the safety and efficacy of this device in treating bifurcation aneurysms remains unknown. We report our preliminary experience with the use of the Pipeline Embolization Device in the management of MCA aneurysms located at the bifurcations, including mid- and long-term follow-up data.

14 agosto 2013

AMERICAN JOURNAL OF NEURORADIOLOGY. Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases

N. Chalouhi, S. Tjoumakaris, L.F. Gonzalez, A.S. Dumont, R.M. Starke, D. Hasan, C. Wu, S. Singhal, L.A. Moukarzel, R. Rosenwasser and P. Jabbour

Background and Purpose: Large and giant intracranial aneurysms are increasingly treated with endovascular techniques. The goal of this study was to retrospectively analyze the complications and long-term results of coiling in large and giant aneurysms (≥10 mm) and identify predictors of outcome.

05 septiembre 2013

AMERICAN JOURNAL OF NEURORADIOLOGY. Intraplaque High-Intensity Signal on 3D Time-of-Flight MR Angiography Is Strongly Associated with Symptomatic Carotid Artery Stenosis

A. Gupta, H. Baradaran, H. Kamel, A. Mangla, A. Pandya, V. Fodera, A. Dunning and P.C. Sanelli

Background and Purpose: Intraplaque hemorrhage in carotid artery atherosclerotic plaque has been shown to be a marker of risk, associated with prior and future ischemic events, and has been associated with regions of intraplaque high-intensity signal on 3D-TOF MRA. We assessed the association of intraplaque high-intensity signal determined on 3D-TOF MRA with the incidence of prior ipsilateral stroke or TIA.

17 octubre 2013

AMERICAN JOURNAL OF NEURORADIOLOGY. Multilevel Assessment of Atherosclerotic Extent Using a 40-Section Multidetector Scanner after Transient Ischemic Attack or Ischemic Stroke

L. Mechtouff, L. Boussel, S. Cakmak, J.-L. Lamboley, M. Bourhis, N. Boublay, A.-M. Schott, L. Derex, T.-H. Cho, N. Nighoghossian and P.C. Douek

Background and Purpose: The first part of this study assessed the potential of MDCT with a CTA examination of the aorta and the coronary, cervical, and intracranial vessels in the etiologic work-up of TIA or ischemic stroke compared with established imaging methods. The objective of the second part of this study was to assess the atherosclerotic extent by use of MDCT in these patients.

01 marzo 2013

SPRINGER. Effect of carotid artery stenting on cerebral blood flow: evaluation of hemodynamic changes using arterial spin labeling

Tae Jin Yun, Chul-Ho Sohn, Moon Hee Han, Byung-Woo Yoon, Hyun-Seung Kang, Jeong Eun Kim, Jin Chul Paeng, Seung Hong Choi, Ji-hoon Kim, Kee-Hyun Chang

Introduction: The purpose of this work was to quantitatively evaluate the hemodynamic changes after carotid artery stenting (CAS) by measuring cerebral blood flow (CBF) using arterial spin labeling (ASL).

01 marzo 2014

SPRINGER. An approach to the symbolic representation of brain arteriovenous malformations for management and treatment planning

Piotr Orlowski, Imran Mahmud, Mudassar Kamran, Paul Summers, Alison Noble, Yiannis Ventikos, James V. Byrne

Introduction: There is currently no standardised approach to arteriovenous malformation (AVM) reporting. Existing AVM classification systems focuses on angioarchitectural features and omit haemodynamic, anatomical and topological parameters intuitively used by therapists.

01 marzo 2014

SPRINGER. Coil embolization in precommunicating (A1) segment aneurysms of anterior cerebral artery

Young Dae Cho, Jun Hyong Ahn, Seung Chai Jung, Chang Hun Kim, Hyun-Seung Kang, Jeong Eun Kim, Young Je Son, Moon Hee Han

Introduction: Precommunicating (A1) segment aneurysms of the anterior cerebral artery are rare and often pose technical challenges for coil embolization due to their distinctive configurations. Clinical and radiologic outcomes of treating such aneurysms through endovascular coil embolization are presented herein.

01 marzo 2014

SPRINGER. Endovascular treatment of head and neck arteriovenous malformations

A. A. Dmytriw, K. G. ter Brugge, T. Krings, R. Agid

Introduction: Head and neck arteriovenous malformations (H&N AVM) are associated with considerable clinical and psychosocial burden and present a significant treatment challenge. We evaluated the presentation, response to treatment, and outcome of patients with H&N AVMs treated by endovascular means at our institution.

01 marzo 2014

NEUROSURGERY. Intravenous Tissue-Type Plasminogen Activator Therapy Is an Independent Risk Factor for Symptomatic Intracerebral Hemorrhage After Carotid Endarterectomy

Vellimana, Ananth K. MD*; Yarbrough, Chester K. MD*; Blackburn, Spiros MD‖; Strom, Russell G. MD*; Pilgram, Thomas K. PhD‡; Lee, Jin-Moo MD, PhD§; Grubb, Robert L. Jr MD*; Rich, Keith M. MD*; Chicoine, Michael R. MD*; Dacey, Ralph G. Jr MD*; Derdeyn, Colin P. MD*,‡,§; Zipfel, Gregory J. MD*,‡,§

Background: Carotid endarterectomy (CEA) for symptomatic carotid artery stenosis and intravenous tissue-type plasminogen activator (IV-tPA) for acute ischemic stroke are proven therapies; however, the safety of CEA in stroke patients who recently received IV-tPA has not been established.

01 marzo 2014

NEUROSURGERY. Long-term Radiographic Results of Stent-Assisted Embolization of Cerebral Aneurysms

Lopes, Demetrius Klee MD; Johnson, Andrew Kelly MD; Kellogg, Robert Givens MD; Heiferman, Daniel Mark MD; Keigher, Kiffon Marie APN

Background: Aneurysmal subarachnoid hemorrhage is a disabling disease. Endovascular coiling provides minimally invasive, effective, and safe treatment of both ruptured and unruptured intracranial aneurysms. Intracranial stents have improved the endovascular treatment of complex aneurysms, but the long-term durability of this treatment modality needs clarification.

01 marzo 2014

NEUROSURGERY. Implantation of Pipeline Flow-Diverting Stents Reduces Aneurysm Inflow Without Relevantly Affecting Static Intra-aneurysmal Pressure

Kerl, Hans U. MD*; Boll, Hanne DVM*; Fiebig, Teresa DVM*; Figueiredo, Giovanna MD*; Förster, Alex MD*; Nölte, Ingo S. MD*; Nonn, Andrea DVM‡; Groden, Christoph MD*; Brockmann, Marc A. MD*,‡

Background: Flow-diverting stent (FDS) implantation is an endovascular treatment option for intracranial aneurysms. However, little is known about the hemodynamic effects.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.