Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ABSTRACT


26 marzo 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Negative Susceptibility Vessel Sign and Underlying Intracranial Atherosclerotic Stenosis in Acute Middle Cerebral Artery Occlusion

S.K. Kim, W. Yoon, T.W. Heo, M.S. Park and H.K. Kang

BACKGROUND AND PURPOSE: The role of MR imaging in predicting underlying intracranial atherosclerotic stenosis before endovascular stroke therapy has not been studied. Our aim was to determine the diagnostic value of the negative susceptibility vessel sign on T2*-weighted gradient-echo MR imaging for predicting underlying intracranial atherosclerotic stenosis in patients with acute MCA occlusion.

24 abril 2015

SPRINGER. Stent-thrombus interaction and the influence of aspiration on mechanical thrombectomy: evaluation of different stent retrievers in a circulation model

Jawid Madjidyar, Julian Hermes, Sandra Freitag-Wolf, Olav Jansen

Introduction: Different devices and techniques are available for endovascular treatment of ischemic stroke. In this in vitro study, we examined the stent-thrombus interaction and the influence of additional aspiration on the efficiency of mechanical thrombectomy with established stent retrievers.

24 abril 2015

SPRINGER. An innovative technique for detecting the caudal end of occluded inferior petrosal sinus in cavernous arteriovenous fistula using intravascular ultrasonography—technical note

Shigeru Yamauchi, Akimasa Nishio, Yoshinobu Takahashi, Kimito Kondo, Taichiro Kawakami, Yuzo Terakawa, Yutaka Mitsuhashi, Kenji Ohata

Introduction: Although cavernous sinus (CS) dural arteriovenous fistulas (d-AVFs) are usually treated with transvenous embolization (TVE) via the inferior petrosal sinus (IPS), IPSs are sometimes thrombosed and angiographically invisible. In such cases, the first obstacle to TVE is detecting the entry to the IPS. We report a new technique for TVE via IPS using intravascular ultrasonography (IVUS).

21 mayo 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Residual Thromboembolic Material in Cerebral Arteries after Endovascular Stroke Therapy Can Be Identified by Dual-Energy CT

A.E. Grams, M. Knoflach, R. Rehwald, J. Willeit, M. Sojer, E.R. Gizewski and B. Glodny

BACKGROUND AND PURPOSE: Dual-energy CT features the opportunity to differentiate among up to 3 different materials because the absorption of x-rays depends on the applied tube voltage and the atomic number of the material. For example, it is possible to distinguish between blood-brain barrier disruption and an intracerebral hemorrhage following treatment for a stroke. The aim of this study was to evaluate whether dual-energy CT is capable of distinguishing intra-arterial contrast agent from residually clotted vessels immediately after endovascular stroke therapy.

30 abril 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Vascular Wall Imaging of Unruptured Cerebral Aneurysms with a Hybrid of Opposite-Contrast MR Angiography

T. Matsushige, Y. Akiyama, T. Okazaki, K. Shinagawa, N. Ichinose, K. Awai and K. Kurisu

BACKGROUND AND PURPOSE: Inflammation and degeneration of the intracranial saccular aneurysm wall play a major role in aneurysm formation, development and subsequent rupture. The aim of this study was to characterize the walls of unruptured intracranial aneurysms by using a hybrid of opposite-contrast MRA at 3T.

07 mayo 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Woven EndoBridge Intrasaccular Flow Disrupter for the Treatment of Ruptured and Unruptured Wide-Neck Cerebral Aneurysms: Report of 55 Cases

D. Behme, A. Berlis and W. Weber

BACKGROUND AND PURPOSE: The safety and efficacy of the Woven EndoBridge (WEB) device for the treatment of cerebral aneurysms have been investigated in several studies. Most of these studies focused on specific aneurysms or a certain WEB device. Our objective was to report the experience of 2 German centers with the WEB device, including technical feasibility, safety, and short-term angiographic outcome.

30 abril 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. The Role of Core Needle Biopsy and Its Impact on Surgical Management in Patients with Medullary Thyroid Cancer: Clinical Experience at 3 Medical Institutions

E.J. Ha, J.H. Baek, D.G. Na, J.-h. Kim, J.K. Kim, H.S. Min, D.E. Song, K.E. Lee and Y.K. Shong

BACKGROUND AND PURPOSE: Medullary thyroid carcinoma is an uncommon malignancy that is challenging to diagnose. Our aim was to present our experience using core needle biopsy for the diagnosis of medullary thyroid carcinoma compared with fine-needle aspiration.

05 febrero 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Fenestrations of Intracranial Arteries

S.B.T. van Rooij, R.S. Bechan, J.P. Peluso, M. Sluzewski and W.J. van Rooij

BACKGROUND AND PURPOSE: Few data are available on the frequency and location distribution of fenestrations of intracranial arteries. We used 3D rotational angiography of all intracranial arteries in a cohort of 179 patients with suspected intracranial aneurysms to assess the prevalence and location of fenestrations and the relation of fenestrations to aneurysms.

26 febrero 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Changes of Time-Attenuation Curve Blood Flow Parameters in Patients with and without Carotid Stenosis

C.-J. Lin, F.-C. Chang, W.-Y. Guo, S.-C. Hung, C.-B. Luo, J. Beilner, M. Kowarschik and W.-F. Chu

BACKGROUND AND PURPOSE: From the time-attenuation curves of DSA flow parameters, maximal intensity, maximal slope, and full width at half maximum of selected vascular points are defined. The study explores the reliability of defining the flow parameters by the time-attenuation curves of DSA.

26 febrero 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. The FRED Flow-Diverter Stent for Intracranial Aneurysms: Clinical Study to Assess Safety and Efficacy

M.A. Möhlenbruch, C. Herweh, L. Jestaedt, S. Stampfl, S. Schönenberger, P.A. Ringleb, M. Bendszus and M. Pham

BACKGROUND AND PURPOSE: Flow-diverter stents are emerging for the endovascular treatment of difficult-to-treat or otherwise untreatable cerebral aneurysms (wide-neck, fusiform, dissecting, blisterlike, or giant). We assessed the clinical safety and efficacy of the Flow-Redirection Endoluminal Device.

19 marzo 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Endovascular Treatment of Wide-Neck Anterior Communicating Artery Aneurysms Using WEB-DL and WEB-SL: Short-Term Results in a Multicenter Study

D.N. Gherasim, B. Gory, R. Sivan-Hoffmann, L. Pierot, H. Raoult, J.-Y. Gauvrit, H. Desal, X. Barreau, D. Herbreteau, R. Riva, F. Ambesi Impiombato, X. Armoiry and F. Turjman

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck anterior communicating artery aneurysms can often be challenging. The Woven EndoBridge (WEB) device is a recently developed intrasaccular flow disrupter dedicated to endovascular treatment of intracranial aneurysms. The aim of this study was to investigate the feasibility, safety, and efficacy of the WEB Dual-Layer and WEB Single-Layer devices for the treatment of wide-neck anterior communicating artery aneurysms.

12 marzo 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. HydroCoils Reduce Recurrence Rates in Recently Ruptured Medium-Sized Intracranial Aneurysms: A Subgroup Analysis of the HELPS Trial

W. Brinjikji, P.M. White, H. Nahser, J. Wardlaw, R. Sellar, H.J. Cloft and D.F. Kallmes

BACKGROUND AND PURPOSE: The HydroCoil Endovascular Aneurysm Occlusion and Packing Study (HELPS) was a randomized, controlled trial comparing HydroCoils with bare-platinum coils. The purpose of this study was to perform a subgroup analysis of angiographic and clinical outcomes of medium-sized aneurysms in the HELPS trial.

01 julio 2015

NEUROSURGERY. Smoking and Intracranial Aneurysm Morphology

Ho, Allen L. MD*,‡; Lin, Ning MD§; Frerichs, Kai U. MD*,‡; Du, Rose MD, PhD*,‡

BACKGROUND: Smoking is a well-known independent risk factor for both aneurysm formation and rupture. There is mounting evidence that aneurysm morphology beyond size can have a significant role in aneurysm formation and rupture risk by its effects on aneurysmal hemodynamics.

01 septiembre 2015

NEUROSURGERY. Detachable-Tip Microcatheters for Liquid Embolization of Brain Arteriovenous Malformations and Fistulas: A United States Single-Center Experience

Herial, Nabeel A. MD*; Khan, Asif A. MD*; Sherr, Gregory T. MD‡; Qureshi, Mushtaq H. MD*; Suri, M. Fareed K. MD‡; Qureshi, Adnan I. MD*

BACKGROUND: The US Food and Drug Administration recently approved a detachable-tip microcatheter, the Apollo microcatheter (eV3, Inc, Irvine, California), to prevent catheter entrapment during embolization of brain arteriovenous malformations (AVMs) using liquid embolic systems.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.