Background and Purpose: Cerebral arterial vasospasm (CVS) is a common complication of aneurysmal subarachnoid hemorrhage strongly associated with neurological deterioration and delayed cerebral ischemia (DCI). The utility of screening for CVS as a surrogate for early detection of DCI, especially in patients without clinical signs of DCI, remains uncertain.
Introduction: CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH.
BACKGROUND AND PURPOSE: Radiographic assessment of cerebral metastasis after stereotactic radiosurgery remains a major challenge in neuro-oncology. It is often difficult to distinguish tumor progression from radiation necrosis in this setting using conventional MR imaging. The objective of this study was to compare the diagnostic sensitivity and specificity of different functional imaging modalities for detecting tumor recurrence after stereotactic radiosurgery.
BACKGROUND AND PURPOSE: Intracranial hemorrhage is the most dreaded complication of neurothrombectomy therapy for acute ischemic stroke. The determinants of intracranial hemorrhage and its impact on clinical course remain incompletely delineated. The purpose of this study is to further investigate the clinical and procedural factors leading to intracranial hemorrhage and to define the clinical impact of different hemorrhagic subtypes.
BACKGROUND AND PURPOSE: Spontaneous intraparenchymal hemorrhage is a dreaded complication of unknown etiology following flow-diversion treatment. Using the International Retrospective Study of the Pipeline Embolization Device registry, we studied demographic, aneurysm, and procedural characteristics associated with intraparenchymal hemorrhage following Pipeline Embolization Device treatment.
BACKGROUND AND PURPOSE: Endovascular coiling of wide-neck intracranial aneurysms is associated with low rates of initial angiographic occlusion and high rates of recurrence. The WEB intrasaccular device has been developed specifically for this indication. To date, there has been no report of the long-term follow-up of a series of patients with aneurysms treated with this type of device, to our knowledge. Our aim was to evaluate a 1-year follow-up of angiographic results in a prospective single-center series of patients treated with the WEB-Single-Layer (SL) device.
BACKGROUND AND PURPOSE: Over the past few years, flow diversion has been increasingly adopted for the treatment of intracranial aneurysms, especially in the paraclinoid and paraophthalmic carotid segment. We compared clinical and angiographic outcomes and complication rates in 2 groups of patients with unruptured carotid-ophthalmic aneurysms treated for 7 years by either standard coil-based techniques or flow diversion.
BACKGROUND AND PURPOSE: The susceptibility vessel sign on MR imaging has been reported to indicate acute occlusion from erythrocyte-rich thrombus. The purpose of this study was to evaluate the influence of the susceptibility vessel sign seen on MR imaging before treatment on the clinical outcome after mechanical thrombectomy for anterior circulation acute stroke.
BACKGROUND AND PURPOSE: Several small case series reported a favorable clinical outcome for emergency stent placement in the extracranial internal carotid artery combined with mechanical thrombectomy in acute stroke. The rate of postinterventional symptomatic intracranial hemorrhages was reported to be as high as 20%. Therefore, we investigated the safety and efficacy of this technique in a large multicentric cohort.
BACKGROUND AND PURPOSE: Various endovascular techniques have been applied to treat blister-like aneurysms. We performed a systematic review to evaluate endovascular treatment for ruptured blister-like aneurysms.
BACKGROUND AND PURPOSE: Semiautomatic measurement of ICA stenosis potentially increases observer reproducibility. In this study, we assessed the diagnostic accuracy and interobserver reproducibility of a commercially available semiautomatic ICA stenosis measurement on CTA and estimated the agreement among different software packages.
BACKGROUND AND PURPOSE: Rupture of the plaque fibrous cap and subsequent thrombosis are the major causes of stroke. This study evaluated morphologic features of plaque rupture in the carotid artery by using optical coherence tomography in vivo.
BACKGROUND AND PURPOSE: Long-term follow-up data of coiled basilar tip aneurysms are scarce, and little is known about the risk of late aneurysm-related adverse events. We followed a cohort of 154 patients with basilar tip aneurysms coiled between 1995 and 2006.
BACKGROUND AND PURPOSE: We report our preliminary results in terms of safety and efficacy in using the low-profile LEO Baby stent for the treatment of large-neck and complex intracranial aneurysms with balloon-then-stent-assisted coiling and single- or dual-stent-assisted coiling.
BACKGROUND AND PURPOSE: The necessity for platelet-inhibition testing before aneurysm treatment in patients premedicated with antiplatelet agents is controversial. Using the International Retrospective Study of Pipeline Embolization Device registry, we studied complication rates in groups of patients who underwent platelet testing and those who did not undergo platelet testing to determine if these test results were associated with improved outcomes.
Cookies Sociales
Son esos botones que permiten compartir el contenido del sitio web en sus redes sociales (Facebook, Twitter y Linkedin, previo tu consentimiento y login) a través de sistemas totalmente gestionados por dichas redes sociales, así como los recursos (pej. videos) y material que se encuentra en nuestra web, y que de igual manera se presta y gestiona completamente por un tercero.