BACKGROUND AND PURPOSE: Robust wall apposition for flow-diverter stents may be important for endothelialization. Using a large series of experimental aneurysms treated with the Pipeline Embolization Device, the objectives of this study were to 1) assess interobserver agreement for the evaluation of wall apposition on posttreatment DSA and evaluate its association with aneurysm occlusion, and 2) measure the relationship between wall apposition assessed with histology and aneurysm occlusion rate after treatment.
BACKGROUND AND PURPOSE: Prophylactic antiplatelet medication is beneficial in decreasing thromboembolic complications during endovascular treatment of unruptured intracranial aneurysms. The efficacy may be limited by variability of individual response to antiplatelet medication, especially clopidogrel. We compared the efficacy of 2 antiplatelet medications, low-dose prasugrel and clopidogrel, in patients undergoing endovascular treatment of unruptured aneurysms.
BACKGROUND AND PURPOSE: Accurately and efficiently modeling the transport of angiographic contrast currently offers the best method of verifying computational fluid dynamics simulations and, with it, progress toward the lofty goal of prediction of aneurysm treatment outcome a priori. This study specifically examines the influence of estimated flow rate and contrast properties on such in silico predictions of aneurysm contrast residence and decay.
BACKGROUND AND PURPOSE: Comparing outcomes between endovascular aneurysm coiling trials can be difficult because of heterogeneity in patients and end points. We sought to understand the impact of geography on aneurysm retreatment in patients enrolled in the Matrix and Platinum Science Trial.
BACKGROUND AND PURPOSE: Although intracranial atherosclerotic disease is often encountered during endovascular treatment for acute vertebrobasilar occlusions, its clinical implication is not well-known. We aimed to evaluate whether intracranial atherosclerotic disease influences the clinical outcomes following endovascular treatment of acute vertebrobasilar occlusive stroke.
BACKGROUND AND PURPOSE: We present the results of a systematic review and meta-analysis examining outcomes of endovascular coiling of wide-neck and wide-neck bifurcation aneurysms with and without stent assistance. The aim of our study was to assess angiographic and clinical outcomes.
BACKGROUND AND PURPOSE: Mechanical thrombectomy with stent retrievers is now the standard therapy for selected patients with ischemic stroke. The technique of A Direct Aspiration, First Pass Technique for the Endovascular Treatment of Stroke (ADAPT) appears promising with a high rate of recanalization. We compared ADAPT versus stent retrievers (the Solitaire device) for efficacy and safety as a front-line endovascular procedure.
BACKGROUND AND PURPOSE: Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model by using patient-specific blood pressure measurements.
BACKGROUND AND PURPOSE: Quantitative data from DSA have become important tools for understanding hemodynamic changes of intracranial lesions. In this study, we evaluated 8 hemodynamic parameters in patients before and after carotid artery angioplasty.
BACKGROUND AND PURPOSE: Mechanical thrombectomy, in addition to intravenous thrombolysis, has become standard in acute ischemic stroke treatment in patients with large-vessel occlusion in the anterior circulation. However, previous randomized controlled stroke trials were not focused on patients with mild-to-moderate symptoms. Thus, there are limited data for patient selection, prediction of clinical outcome, and occurrence of complications in this patient population. The purpose of this analysis was to assess clinical and interventional data in patients treated with mechanical thrombectomy in case of ischemic stroke with mild-to-moderate symptoms.
BACKGROUND AND PURPOSE: Intracranial stents have become extremely important in the endovascular management of complex intracranial aneurysms. Sizing and landing zone predictions are still very challenging steps in the procedure. Virtual stent deployment may help therapeutic planning, device choice, and hemodynamic simulations. We aimed to assess the predictability of our recently developed virtual deployment model by comparing in vivo and virtual stents implanted in a consecutive series of patients presenting with intracranial aneurysms.
BACKGROUND: Gamma knife radiosurgery (GKRS) is well established in the management of inaccessible, recurrent, or residual benign skull base meningiomas. Most series report clinical outcome parameters and complications in the short intermediate period after radiosurgery. Reports of long-term tumor control and neurological status are still lacking.
BACKGROUND: The risk of hemorrhage from a brain arteriovenous malformation (bAVM) is increased when an associated proximal intracranial aneurysm (APIA) is present. Identifying factors that are associated with APIA may influence the prediction of hemorrhage in patients with bAVM.
BACKGROUND: Along with subarachnoid hemorrhage (SAH), a ruptured aneurysm may also cause an intracerebral hematoma (ICH), which negatively impacts the functional outcome of SAH.
BACKGROUND: There is scant information on in-stent stenosis after flow diversion treatment of intracranial aneurysms with the Pipeline Embolization Device (PED).
Cookies Sociales
Son esos botones que permiten compartir el contenido del sitio web en sus redes sociales (Facebook, Twitter y Linkedin, previo tu consentimiento y login) a través de sistemas totalmente gestionados por dichas redes sociales, así como los recursos (pej. videos) y material que se encuentra en nuestra web, y que de igual manera se presta y gestiona completamente por un tercero.
Si no acepta estas cookies, no podrá compartir nuestro contenido a través de los botones, y en su caso, no podrás visualizar el contenido de terceros que hayamos incrustado en el sitio.
No las utilizamos