Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ESTUDIOS


01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. Percutaneous Microwave Ablation of Hepatocellular Carcinoma with a Gas-Cooled System: Initial Clinical Results with 107 Tumors

Timothy J. Ziemlewicz, MD, J. Louis Hinshaw, MD , Meghan G. Lubner, MD , Christopher L. Brace, PhD , Marci L. Alexander, RN , Parul Agarwal, MD , Fred T. Lee Jr, MD

Purpose: To retrospectively review the results of hepatocellular carcinoma (HCC) treatment with a high-power, gas-cooled, multiantenna-capable microwave device.

01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. Percutaneous Discal Cyst Rupture in a Professional Football Player Using Sublaminar Epidural Injection for Thecal Sac Displacement

Michael V. Friedman, MD, Andrew Park, MD , David Bumpass, MD , Jack W. Jennings, MD, PhD , Matthew J. Matava, MD

A case of percutaneous discal cyst rupture in a 25-year-old professional American football player is reported. The patient presented with a 3-day history of severe left-sided back pain. Magnetic resonance imaging examination demonstrated a discal cyst effacing the left L4-L5 lateral recess, with interposed thecal sac. A sublaminar epidural injection was performed displacing the thecal sac, exposing the discal cyst, and allowing for percutaneous perforation. The patient had complete resolution of symptoms after discal cyst rupture and was able to compete in a professional football game 3 days later. Computed tomography–guided percutaneous rupture is a therapeutic modality that may be considered for treatment of a symptomatic discal cyst.

01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. Prostatic Artery Embolization for Treatment of Benign Prostatic Hyperplasia in Patients with Prostates > 90 g: A Prospective Single-Center Study

André Moreira de Assis, MD, Airton Mota Moreira, MD, PhD , Vanessa Cristina de Paula Rodrigues, NP , Eduardo Muracca Yoshinaga, MD , Alberto Azoubel Antunes, MD, PhD , Sardis Honoria Harward, MPH , Miguel Srougi, MD, PhD , Francisco Cesar Carnevale, MD, PhD

Purpose: To describe the safety and efficacy of prostatic artery embolization (PAE) with spherical microparticles to treat lower urinary tract symptoms associated with benign prostatic hyperplasia in patients with prostate volume > 90 g.

01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. Strut Penetration: Local Complications, Breakthrough Pulmonary Embolism, and Retrieval Failure in Patients with Celect Vena Cava Filters

Aaron Bos, MD, Thuong Van Ha, MD , Darren van Beek, MD , Michael Ginsburg, MD , Steven Zangan, MD , Rakesh Navuluri, MD , Jonathan Lorenz, MD , Brian Funaki, MD

Purpose: To investigate strut penetration in patients with Celect filters, specifically local complications and association with breakthrough pulmonary embolism (PE) or retrieval failure.

01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. Bard Denali Inferior Vena Cava Filter Fracture and Embolization Resulting in Cardiac Tamponade: A Device Failure Analysis

William T. Kuo, MD, Scott W. Robertson, PhD

A 46-year-old woman underwent inferior vena cava filter placement before bariatric surgery and returned within 6 months for routine removal. She complained of a 1-week history of severe chest pain, and during retrieval, two fractured filter components were identified including one arm in the right ventricle. The filter body and one fragment were successfully retrieved, but the fragment in the right ventricle was refractory to percutaneous retrieval. During open-heart surgery, the fragment was found traversing through the ventricular wall resulting in cardiac tamponade. Electron microscopic fragment analysis revealed high-cycle metal fatigue indicating the filter design failed to withstand this patient’s natural inferior vena cava biomechanical motions.

01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. Muraglitazar-Eluting Bioabsorbable Vascular Stent Inhibits Neointimal Hyperplasia in Porcine Iliac Arteries

Ilkka Uurto, MD, Mari Hämäläinen, PhD , Velipekka Suominen, MD , Marita Laurila, MD , Andres Kotsar, MD , Taina Isotalo, MD , Teuvo L.J. Tammela, MD , Minna Kellomäki, Dr Tech , Juha-Pekka Salenius, MD

Purpose: To evaluate the biocompatibility of a new muraglitazar-eluting polylactide copolymer stent and investigate its ability to prevent the formation of intimal hyperplasia.

01 febrero 2015

CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. Transarterial Chemoembolization for Hepatocellular Carcinoma with a New Generation of Beads: Clinical–Radiological Outcomes and Safety Profile

Carlo Spreafico, Tommaso Cascella, Antonio Facciorusso, Carlo Sposito, Lanocita Rodolfo, Carlo Morosi, Enrico M. Civelli, Marta Vaiani, Sherrie Bhoori, Alessandro Pellegrinelli, Alfonso Marchianò, Vincenzo Mazzaferro

Purpose: To evaluate the short-term safety and efficacy of the new generation of 70–150 µm drug-eluting beads (M1 DEB) in patients with hepatocellular carcinoma undergoing transarterial chemoembolization (TACE) as a primary therapy or as a bridge to liver transplantation (LT).

01 enero 2015

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY. The Hangman Technique: A Modified Loop Snare Technique for the Retrieval of Inferior Vena Cava Filters with Embedded Hooks

Ramsey Al-Hakim, MD , Justin P. McWilliams, MD , William Derry, MD , Stephen T. Kee, MD

The loop snare technique is a method for inferior vena cava (IVC) filter retrieval that creates a wire loop between the filter legs; this technique may fail in cases with an embedded hook. This report describes the hangman technique, a modified loop snare technique for filter retrieval that creates a wire loop between the filter neck and IVC wall for release of embedded filter hooks. The hangman technique was attempted in 11 cases complicated by tilt (mean tilt, 13.3 degrees ± 3.9) and an embedded hook (mean dwell time, 194.5 d) with a retrieval success rate of 81.8% (9 of 11 cases) and no associated complications.

01 diciembre 2013

RADIOLOGY. Irreversible Electroporation: Treatment Effect Is Susceptible to Local Environment and Tissue Properties

Eliel Ben-David, MD, Muneeb Ahmed, MD, Mohammad Faroja, MD, Marwan Moussa, MD, Ayelet Wandel, MD, Jacob Sosna, MD, Liat Appelbaum, MD, Isaac Nissenbaum, BSc, S. Nahum Goldberg, MD

Irreversible electroporation (IRE) is an image-guided ablation modality that uses an electrical field without thermal energy to induce cell damage, and ultimately, cell death (1,2). Interest in IRE clinical application is increasing, especially for use in locations where thermal damage is a substantial concern, such as the pancreas (3,4) or near vital structures such as the bile ducts in the liver (2). Given that it is less sensitive to inherent tissue characteristics such as vascular heat-sink effects that limit the efficacy of thermal ablation modalities that use radiofrequency, microwave, or cryotherapy (5–7), IRE holds promise for effective treatment of tumors adjacent to blood vessels (8).

01 diciembre 2013

RADIOLOGY. Quantitative Elastography of Liver Fibrosis and Spleen Stiffness in Chronic Hepatitis B Carriers: Comparison of Shear-Wave Elastography and Transient Elastography with Liver Biopsy Correlation

Vivian Yee-fong Leung, PhD, Jiayun Shen, MSc, Vincent Wai-sun Wong, MD, Jill Abrigo, FRCR, Grace Lai-hung Wong, MD, Angel Mei-ling Chim, MSc, Shirley Ho-ting Chu, MSc, Anthony Wing-hung Chan, MD, Paul Cheung-lung Choi, MD, Anil T. Ahuja, MD, Henry Lik-yuen Chan, MD, Winnie Chiu-wing Chu, MD

Patients with chronic hepatitis B are at increased risk of cirrhosis. Assessment of fibrosis has important prognostic implications that guide clinical therapy (1,2). Though liver biopsy is still the reference standard for diagnosis and grading of fibrosis, it is invasive and carries risk of complications.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.