Purpose: Locoregional therapy for hepatocellular carcinoma (HCC) can be challenging in patients with a transjugular intrahepatic portosystemic shunt (TIPS). This study compares safety and imaging response of ablation, chemoembolization, radioembolization, and supportive care in patients with both TIPS and HCC.
Ovarian and other pelvic varices (such as in the distribution of the internal iliac veins) are not an infrequent finding in adult women, and particularly those who have previously had at least one pregnancy associated with a vaginal delivery or at least a significant trial of labour. However, they are also well described in asymptomatic parous women.
Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant tumors located near large vessels or bile ducts. The presence of metal objects in the ablation zone, such as Wallstents, is generally considered a contraindication for IRE, because tissue heating due to power conduction may lead to thermal complications. This report describes a 66-year-old female with a Bismuth–Corlette stage IV unresectable cholangiocarcinoma with a metallic Wallstent in the common bile duct, who was safely treated with percutaneous IRE with no signs for relapse 1 year after the procedure.
Purpose: Using large-core biopsy needles in CT-guided percutaneous transthoracic needle biopsies (PTNB) may be advantageous in terms of larger specimens, which facilitate more extensive histopathological, immunohistochemical, and molecular examination of tumor tissue. The aim of this study was to evaluate the success rate and safety in CT-guided PTNB using 10G large-core biopsy needles.
Purpose: To prospectively compare SIRT and DEB-TACE for treating hepatocellular carcinoma (HCC).
Objective: This retrospective study reports our experience using splenic arterial particle embolization and coil embolization for the treatment of sinistral portal hypertension (SPH) in patients with and without gastric bleeding.
Purpose: To optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.
Purpose: Different techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions.
Purpose: The minimally important difference (MID) represents the smallest change in score on patient-reported outcome measures that is relevant to patients. The aim of this study was to introduce the MID for the Vascular Quality of Life Questionnaire (VascuQol) and the walking impairment questionnaire (WIQ) for patients with intermittent claudication (IC).
To evaluate the efficacy and safety of microwave (MW) ablation compared with radiofrequency (RF) ablation for hepatic lesions by using meta-analytic techniques. Overall, 16 studies involving 2,062 patients were included. MW ablation was found to have significantly better 6-year overall survival than RF ablation (odds ratio, 1.64, 95% confidence interval, 1.15–2.35), but this was based on a few articles (n = 3 of 16). MW ablation and RF ablation had similar 1–5-year overall survival, disease-free survival, local recurrence rate, and adverse events. Based on similar safety and efficacy outcomes, either MW ablation or RF ablation may be used for effective local hepatic therapy.
This document is an educational tool designed to assist practitioners in providing appropriate radiologic care for patients. Practice Parameters and Technical Standards are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the American College of Radiology (ACR) and our collaborating medical specialty societies caution against the use of these documents in litigation in which the clinical decisions of a practitioner are called into question.
Purpose: To evaluate long-term patency and symptomatic recurrence rates following transjugular intrahepatic portosystemic shunt (TIPS) creation with expanded polytetrafluoroethylene (ePTFE)–covered stent grafts and to determine the necessity of extended clinical follow-up beyond 2 years after TIPS creation.
PURPOSE: Clinical cases of stent-fractures show that corrosion behavior might play a role in these fractures. Implanted in vivo, especially in combination with other implanted foreign materials, these metallic products are exposed to special conditions, which can cause a process of corrosion. Here, we aimed to test the corrosion potential of stents made of different materials in an in vitro setting.
PURPOSE: We aimed to assess hemodynamic changes in calf perforator veins (PVs) after endovenous laser ablation (EVLA) of saphenous veins.
PURPOSE: Knowledge of the anatomic variations of the posterior intercostal artery (PICA) and its major branches is important during transthoracic procedures and surgery. We aimed to identify the anatomic features and variations of the lateral intercostal artery perforator (LICAP) of the PICA with selective PICA arteriography.
Cookies Sociales
Son esos botones que permiten compartir el contenido del sitio web en sus redes sociales (Facebook, Twitter y Linkedin, previo tu consentimiento y login) a través de sistemas totalmente gestionados por dichas redes sociales, así como los recursos (pej. videos) y material que se encuentra en nuestra web, y que de igual manera se presta y gestiona completamente por un tercero.