Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ABSTRACT


01 abril 2014

JOUNAL OF VASCULAR SURGERY. Outcome and clinical significance of delayed endoleaks after endovascular aneurysm repair

Wei Zhou, MD , Eddie Blay Jr., BA , Vinit Varu, MD , Syed Ali, BS , Michelle Qiushuang Jin, BA , Lisa Sun, MS , Jin Hyun Joh, MD, PhD

Objective: Endovascular aneurysm repair (EVAR) is considered the standard therapy for most patients with abdominal aortic aneurysm (AAA). Endoleak is a well-known EVAR-related complication that requires long-term follow-up. However, patient follow-up is often challenging outside clinical trials. We sought to evaluate the incidence and the effect of delayed endoleaks in a Veterans Administration (VA) health care system where long-term follow-up is ensured.

01 abril 2014

JOUNAL OF VASCULAR SURGERY. Type II endoleak is an enigmatic and unpredictable marker of worse outcome after endovascular aneurysm repair

Enrico Cieri, MD, PhD , Paola De Rango, MD, PhDemail address , Giacomo Isernia, MD , Gioele Simonte, MD , Andrea Ciucci, MD , Gianbattista Parlani, MD , Fabio Verzini, MD, PhD, FEBVS , Piergiorgio Cao, MD, FRCS

Background: This study analyzed predictors and the long-term consequence of type II endoleak in a large series of elective endovascular abdominal aneurysm repairs (EVARs).

01 abril 2014

JOUNAL OF VASCULAR SURGERY. Safety and feasibility of adjunctive dexamethasone infusion into the adventitia of the femoropopliteal artery following endovascular revascularization

Christopher D. Owens, MD, MSc , Warren J. Gasper, MD , Joy P. Walker, MD , Hugh F. Alley, BA , Michael S. Conte, MD , S. Marlene Grenon, MD

Objective: Restenosis following endovascular treatment of the femoropopliteal segment is associated with the inflammatory response produced in the artery wall at the time of the procedure. Although local drug delivery to the superficial femoral and popliteal arteries promises improved patency, data are currently limited. We hypothesized that improved percutaneous delivery of an anti-inflammatory compound into the adventitia of the femoropopliteal at the time of endovascular treatment would be safe, feasible, and decrease the inflammatory response.

01 abril 2014

JOUNAL OF VASCULAR SURGERY. Metabolic syndrome is associated with type II endoleak after endovascular abdominal aortic aneurysm repair

Michael R. Hall, MD , Clinton D. Protack, MD , Roland Assi, MD , Willis T. Williams, MD , Daniel J. Wong, BS , Daniel Lu, BS , Bart E. Muhs, MD, PhD , Alan Dardik, MD, PhD

Objective: Type II endoleak is usually a benign finding after endovascular abdominal aortic aneurysm repair (EVAR). In some patients, however, type II endoleak leads to aneurysm sac expansion and the need for further intervention. We examined which factors, in particular the components of metabolic syndrome (MetS), would lead to an increase risk of endoleak after EVAR.

01 abril 2014

CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. Anatomic Risk Factors for Type-2 Endoleak Following EVAR: A Retrospective Review of Preoperative CT Angiography in 326 patients

Thomas J. Ward, Stuart Cohen, Rahul S. Patel, Edward Kim, Aaron M. Fischman, Francis S. Nowakowski, Sharif H. Ellozy, Peter L. Faries, Michael L. Marin, Robert A. Lookstein

Purpose: We describe the anatomic characteristics on preoperative CT angiography (CTA) that predispose to type-2 endoleaks after endovascular aneurysm repair (EVAR) for an abdominal aortic aneurysms (AAA).

01 abril 2014

CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. Endovascular Aortic Repair With the Chimney Technique Using the Ultra Low–Profile Ovation Stent-Graft for Juxtarenal Aneurysms Having Small Iliac Access Vessels

Alexander Massmann, Ferdinand Serracino-Inglott, Arno Buecker

Purpose: To report the first experience using the chimney technique in combination with the latest-generation low-profile stent-graft to seal abdominal aortic aneurysms having a very short neck (proximal sealing zone) and difficult access due to very small iliac vessels.

01 abril 2014

RADIOLOGY. Volumetric Quantification of Type II Endoleaks: An Indicator for Aneurysm Sac Growth Following Endovascular Abdominal Aortic Aneurysm Repair

Shadpour Demehri, MD, Jason Signorelli, MS, Kanako K. Kumamaru, MD, PhD, Nicole Wake, MS, Elizabeth George, MBBS, Michael Hanley, MD1, Michael L. Steinger, MD, Edwin Charles Gravereaux, MD, Frank J. Rybicki, MD, PhD

Purpose: To test the hypothesis that type II endoleak cavity volume (ECV) and endoleak cavity diameter (ECD) measurements are accurate indicators of aneurysm sac volume (ASV) enlargement in patients who undergo endovascular aneurysm repair (EVAR) in the abdominal aorta.

01 marzo 2014

JOURNAL OF VASCULAR SURGERY. Comparative effectiveness of endovascular versus open repair of ruptured abdominal aortic aneurysm in the Medicare population

Samuel T. Edwards, MD , Marc L. Schermerhorn, MD , A. James O Malley, PhD , Rodney P. Bensley, MD , Rob Hurks, MD, PhD , Philip Cotterill, PhD , Bruce E. Landon, MD, MBA, MSc

Objective: Endovascular aortic repair (EVAR) for abdominal aortic aneurysm (AAA) is increasingly used for emergent treatment of ruptured AAA (rAAA). We sought to compare the perioperative and long-term mortality, procedure-related complications, and rates of reintervention of EVAR vs open aortic repair of rAAA in Medicare beneficiaries.

01 marzo 2014

JOURNAL OF VASCULAR SURGERY. Pathology-specific secondary aortic interventions after thoracic endovascular aortic repair

Salvatore T. Scali, MD , Adam W. Beck, MD , Khayree Butler, MD , Robert J. Feezor, MD , Tomas D. Martin, MD , Philip J. Hess, MD , Thomas S. Huber, MD, PhD , Catherine K. Chang, MD

Objective: Despite improved short-term outcomes, concerns remain regarding durability of thoracic endovascular aortic repair (TEVAR). The purpose of this analysis was to evaluate the pathology-specific incidence of secondary aortic interventions (SAI) after TEVAR and their impact on survival.

01 marzo 2014

JOURNAL OF VASCULAR SURGERY. Experience with a novel custom-made fenestrated stent graft in the repair of juxtarenal and type IV thoracoabdominal aneurysms

Alexander E. Rolls, MRCS , Michael Jenkins, MS, FRCS , Colin D. Bicknell, MD, FRCS , Celia V. Riga, MD, MRCS , Nick J. Cheshire, MD, FRCS , Nick Burfitt, FRCR , Mohamad Hamady, MD, FRCR

Objective: Fenestrated stent grafting has become increasingly popular as a means to manage complex aortic pathology, including juxta- and pararenal aneurysms. The design of a recently developed custom-made fenestrated stent graft, in theory, confers advantages when managing anatomically challenging aortic morphology. This study evaluated its feasibility in anatomically challenging scenarios.

01 marzo 2014

JOURNAL OF VASCULAR SURGERY. Outcomes of open and endovascular repair for ruptured and nonruptured internal iliac artery aneurysms

Muhammad A. Rana, MBBS , Manju Kalra, MBBS , Gustavo S. Oderich, MD , Eileen de Grandis, MD , Peter Gloviczki, MD , Audra A. Duncan, MD , Steven S. Cha, MS , Thomas C. Bower, MD

Objective: To evaluate outcomes of open (OR) and endovascular repair (II-EVAR) of internal iliac artery aneurysms (IIAAs) with or without preservation of internal iliac artery (IIA) flow.

01 marzo 2014

JOURNAL OF VASCULAR SURGERY. Decision analysis model of open repair versus endovascular treatment in patients with asymptomatic popliteal artery aneurysms

Wouter Hogendoorn, MD , Felix J.V. Schlösser, MD, PhD , Frans L. Moll, MD, PhD , Bart E. Muhs, MD, PhD , M.G. Myriam Hunink, MD, PhD , Bauer E. Sumpio, MD, PhD

Objective: Repair is indicated of asymptomatic popliteal artery aneurysms (aPAAs) that are >2 cm. Endovascular PAA repair with covered stents (stenting) is increasingly used. It is, however, unclear when an endovascular approach is preferred to traditional open repair with great saphenous vein bypass (GSVB). The goal of this study was to assess the treatment options for aPAAs using decision analysis.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.