Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ABSTRACT


09 octubre 2012

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Blood Transfusion and the Risk of Acute Kidney Injury After Transcatheter Aortic Valve Implantation

Rutger-Jan Nuis, MSc, Josep Rodés-Cabau, MD, Jan-Malte Sinning, MD, Leen van Garsse, MD, Joelle Kefer, MD, PhD, Johan Bosmans, MD, PhD, Antonio E. Dager, MD, Nicolas van Mieghem, MD, Marina Urena, MD, Georg Nickenig, MD, PhD, Nikos Werner, MD, PhD, Jos Maessen, MD, PhD, Parla Astarci, MD, Sergio Perez, MD, Luis M. Benitez, MD, Eric Dumont, MD, Ron T. van Domburg, PhD and Peter P. de Jaegere, MD, PhD

Background—Blood transfusion is associated with acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI). We sought to elucidate in more detail the relation between blood transfusion and AKI and its effects on short- and long-term mortality. Circulation: Cardiovascular Interventions. 2012; 5: 680-688 Published online before print October 9, 2012, doi: 10.1161/​CIRCINTERVENTIONS.112.971291. Copyright © 2012 American Heart Association, Inc. All rights reserved.

25 septiembre 2012

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Optical Coherence Tomography Findings in Lesions After Sirolimus-Eluting Stent Implantation With Peri-Stent Contrast Staining

Takeshi Tada, MD, PhD, Kazushige Kadota, MD, PhD, Shingo Hosogi, MD, PhD, Shunsuke Kubo, MD, Masatomo Ozaki, MD, Mitsuru Yoshino, MD, Koshi Miyake, MD, Haruki Eguchi, MD, Noriyuki Ohashi, MD, Yuki Hayakawa, MD, Naoki Saito, MD, Suguru Otsuru, MD, Daiji Hasegawa, MD, Yoshikazu Shigemoto, MD, Seiji Habara, MD, Masao Imai, MD, PhD, Hiroyuki Tanaka, MD, Yasushi Fuku, MD, Naoki Oka, MD, PhD, Harumi Kato, MD, Hiroyuki Yamamoto, MD, Satoki Fujii, MD, Tsuyoshi Goto, MD and Kazuaki Mitsudo, MD

Background—We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. Circulation: Cardiovascular Interventions. 2012; 5: 649-656 Published online before print September 25, 2012, doi: 10.1161/​CIRCINTERVENTIONS.112.968487. Copyright © 2012 American Heart Association, Inc. All rights reserved.

25 septiembre 2012

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Incidence and Clinical Impact of Stent Fracture After Everolimus-Eluting Stent Implantation

Shoichi Kuramitsu, MD, Masashi Iwabuchi, MD, Takuya Haraguchi, MD, Takenori Domei, MD, Ayumu Nagae, MD, Makoto Hyodo, MD, Kyohei Yamaji, MD, Yoshimitsu Soga, MD, Takeshi Arita, MD, Shinichi Shirai, MD, Katsuhiro Kondo, MD, Kenji Ando, MD, Koyu Sakai, MD, Masahiko Goya, MD, Yoshitaka Takabatake, MD, Shinjo Sonoda, MD, Hiroyoshi Yokoi, MD, Fumitoshi Toyota, MD, Hideyuki Nosaka, MD and Masakiyo Nobuyoshi, MD

Background—Stent fracture (SF) after drug-eluting stent implantation has recently become an important concern because of its potential association with in-stent restenosis and stent thrombosis. However, the incidence and clinical impact of SF after everolimus-eluting stent implantation remain unclear. Circulation: Cardiovascular Interventions. 2012; 5: 663-671 Published online before print September 25, 2012, doi: 10.1161/​CIRCINTERVENTIONS.112.969238. Copyright © 2012 American Heart Association, Inc. All rights reserved.

18 septiembre 2012

STROKE. Critique of Closure or Medical Therapy for Cryptogenic Stroke With Patent Foramen Ovale

David E. Thaler, MD, PhD; Andreas Wahl, MD

It is widely accepted that venous thromboemboli can gain access to the left atrium through a patent foramen ovale (PFO). In stroke patients, this mechanism is generally presumed when no other source of stroke is found and a PFO is discovered. Rarely is a thrombus caught straddling the interatrial septum across a PFO. Stroke. 2012; 43: 3147-3149 Published online before print September 18, 2012, doi: 10.1161/​STROKEAHA.112.659599. Copyright © 2012 American Heart Association, Inc. All rights reserved.

01 junio 2010

INTERVENTIONAL CARDIOLOGY. Drug-eluting Stents: The Next Generation

James A Shand, Ian BA Menown

It is accepted that polymer breakdown occurs through various mechanisms, but for the purpose of this article the exact terminology has been simplified and bioabsorbable will be used to describe all mechanisms of polymer breakdown. Early investigations noted a wide range of vascular inflammatory response to different bioabsorbable polymers. However, in a separate investigation it was noted that high molecular weight poly-L-lactic acid caused no acute or chronic inflammation in porcine coronary arteries.[18] It should also be noted that despite a possible proinflammatory stimulus the polymer will completely degrade within 6–9 months, usually through hydrolysis to leave only a BMS in situ. This has subsequently led to large multicenter investigations of next-generation DES utilizing bioabsorbable polymers.

01 octubre 2012

JACC. Drug-Eluting Stents for the Treatment of Left Main Coronary Artery Disease with Bifurcated Lesions: A Comparison with Sirolimus, Paclitaxel, Zotarolimus (Endeavor Resolute), BiolimusA9, EPC Capture and Everolimus-Eluting Stent

TCT-707 - Sunao Nakamura; Hisao Ogawa; Jang-Ho Bae; Yeo Cahyadi; Wasan Udayachalerm; Damras Tresukosol; Sudaratana Tansuphaswadikul

Background: The aim of this study is to compare the safety, efficacy and durability of Sirolimus (SES), Paclitaxel (PES), Zotarolimus (ZES-R/ Endeavor Resolute), BiolimusA9 (BES), EPC capture (ECS) and Everolimus-eluting stent (EES) on the outcome of patients with left main coronary arteries (LMT) stenosis

01 enero 2009

EURO INTERVENTION. In vivo evaluation of a biolimus eluting nickel titanium self expanding stent with overlapping balloon expandable drug eluting and bare metal stents in a porcine coronary model

Oficial Journal of Euro PCR

Aims: Long lesions and complex vessel anatomy frequently require the use of overlapping stents to treat a lesion. The purpose of this study was to evaluate the long-term effects of overlapping the Axxess Biolimus A9™ eluting stent (BES) with two of the most commonly used, commercially available drug eluting stents. These stents were compared to BxVelocity bare metal (BMS) stents in a porcine coronary stent-injury model.

16 julio 2004

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. Acute and long-term clinical and angiographic outcome after S-Stent implantation: S-Stent multicenter safety and efficacy trial

Charles Chan, Yean-Leng Lim PhD, Teguh Santoso MD, Damras Tresukosol MD, Yean-Teng Lim, Shinjo Sonoda MD, Peter Fitzgerald MD

Abstract: The purpose of this study is to demonstrate safety and effectiveness of the S-Stent in de novo coronary lesions treated with conventional percutaneous coronary balloon angioplasty. Between January 2000 and June 2001, 120 patients were prospectively enrolled at four study centers. Patients were treated with coronary stenting in a total of 137 lesions. Procedural success was achieved in 100% of 137 attempted lesions. Clinical success was 99.8%. In-hospital mortality was 0.8%; myocardial infarction occurred in 0.8% and stent thrombosis in 0.8%. After stent implantation, the minimal lumen diameter increased from 0.92 ± 0.43 to 2.74 ± 0.36 mm (P < 0.0001) and the percent diameter stenosis decreased from 68.0 ± 16.2 to 4.5 ± 12.0 (P < 0.0001). At 6-month follow-up, the percent diameter stenosis was 33.5 ± 21.3 and the angiographic restenosis rate was 16.5%. Target lesion revascularization was required in 12 patients (10.1%). We conclude that the use of S-Stent for coronary intervention resulted in a high procedural success rate and low angiographic restenosis at 6 months after implantation. Catheter Cardiovasc Interv 2004;62:439–444. © 2004 Wiley-Liss, Inc.

01 noviembre 2006

EXPERT REVIEW OF MEDICAL DEVICES. BioMatrix® Biolimus A9®-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease

Eberhard Grube and Lutz Buellesfeld

Drug-eluting stent technology consisting of a bare metal stent, carrier coating, bioactive drug and delivery system, offers an almost infinite range of possible device configurations. A growing understanding of the mechanisms of restenosis allows for the design of synergistic functions within these components, thus providing a basis for new and improved products. The BioMatrix® stent (Biosensors Interventional Technologies Pte Ltd., Singapore) elutes the new sirolimus derivative Biolimus A9® from a biodegradable polylactic acid polymer. Biolimus A9 possesses enhanced anti-inflammatory and antiproliferative activity with an improved pharmacokinetic profile. Permanent polymer-carrier-based platforms may be associated with inflammation, late thrombosis and restenosis. The BioMatrix, with its asymmetric and abluminal coating, releases Biolimus A9 into the vessel wall while the polylactic acid polymer is resorbed by surrounding tissues. Clinical studies have demonstrated the BioMatrix to be well tolerated and effective, and it has now become the subject of an aggressive clinical program.

01 febrero 2007

EURO INTERVENTION. AXXESS™ Biolimus A9® eluting bifurcation stent system

Oficial Journal of Euro PCR

Patients with multi-vessel disease, diabetes and bifurcation lesions are among some of the most difficult lesion subgroups to treat effectively with percutaneous coronary intervention. Historically, bifurcation lesion location has been shown to be a predictor for major adverse cardiac events1. More recent studies of PCI using drug eluting stents (DES) in bifurcation lesions show that while target lesion revascularisation (TLR) rates are reduced, these lesions continue to be difficult to classify, difficult to treat, and associated with elevated complication rates such as periprocedural non-Q-wave MI2, side branch occlusion, and stent thrombosis3. These problems are not likely to be solved by procedure modifications alone; stent design modifications will play a role as well.

01 agosto 2009

EURO INTERVENTION. Biolimus-eluting biodegradable polymer versus sirolimuseluting permanent polymer stent performance in long lesions: results from the LEADERS multicentre trial substudy

Oficial Journal of Euro PCR

Aims: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.