Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ESTUDIOS


01 marzo 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Embolic Protection Devices in Transcatheter Aortic Valve Replacement

Arie Steinvil, Richard T. Benson and Ron Waksman

The initially reported periprocedural neurological events rates associated with transcatheter aortic valve replacement raised concerns that ultimately led to the development and to the clinical research of novel embolic protection devices. Although the reduction of clinical stroke is a desired goal, the current research design of embolic protection devices focuses on surrogate markers of the clinical disease, primarily on silent central nervous system lesions observed in postprocedural diffuse-weighted magnetic resonance imaging and cognitive function testing. As the mere presence of particulate debris in brain matter may not correlate with the extent of brain injury, cognitive function, or quality of life, the clinical significance of embolic protection devices has yet to be determined, and interpretation of study results with regard to real-life clinical use should be viewed accordingly. The purpose of this article is to provide an overview of the updated ongoing clinical research on embolic protection devices and present its major caveats.

01 marzo 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Three-Dimensional Printing for Planning Occlusion Procedure for a Double-Lobed Left Atrial Appendage

Yiting Fan, Ka-Wai Kwok, Yiqun Zhang, Gary Shing-Him Cheung, Anna Kin-Yin Chan and Alex Pui-Wai Lee

Catheter-based LAA occlusion has emerged as an alternative to oral anticoagulation for reducing atrial fibrillation–related stroke risk. Currently, procedural planning for LAA occlusion was guided by TEE and fluoroscopy and procedural success rate is high. However, marked age- and sex-related differences in LAA anatomy exist. The existence of multilobed appendages is important in the accurate TEE evaluation of LAA. Fifty-four percent of LAAs had 2 lobes. Because lobes exist in different planes, imaging must be done in multiple planes to visualize the entire LAA. Complexity and variability of LAA morphology sometimes pose challenges to device implantation, potentially leading to repeated deployment attempts, incomplete seal, procedural complications, and failure. The process of 3D printing refers to the conversion of 3D computerized models into physical replica. It is now feasible to 3D print patient-specific LAA models from 3D data sets acquired by 3D imaging techniques using materials that mechanically mimic atrial soft tissues. This report illustrates the techniques and advantages of 3D printing in facilitating LAA occlusion in cases with challenging LAA anatomy by enhancing appreciation of LAA morphology and enabling simulation of device deployment before the actual procedure.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Outcomes With Intravascular Ultrasound-Guided Stent Implantation: A Meta-Analysis of Randomized Trials in the Era of Drug-Eluting Stents

Islam Y. Elgendy, Ahmed N. Mahmoud, Akram Y. Elgendy and Anthony A. Bavry

Background: In the era of drug-eluting stents, it is unknown if intravascular ultrasound (IVUS) guidance for percutaneous coronary intervention should be routinely endorsed. This study aimed to determine if IVUS-guided stent implantation is associated with improved outcomes.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Occupational Health Risks in Cardiac Catheterization Laboratory Workers

Maria Grazia Andreassi, Emanuela Piccaluga, Giulio Guagliumi, Maurizio Del Greco, Fiorenzo Gaita, Eugenio Picano and on behalf of the Healthy Cath Lab Study Group

Background: Orthopedic strain and radiation exposure are recognized risk factors in personnel staff performing fluoroscopically guided cardiovascular procedures. However, the potential occupational health effects are still unclear. The purpose of this study was to examine the prevalence of health problems among personnel staff working in interventional cardiology/cardiac electrophysiology and correlate them with the length of occupational radiation exposure.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Effectiveness of Arterial Closure Devices for Preventing Complications With Percutaneous Coronary Intervention

Neil J. Wimmer , Eric A. Secemsky , Laura Mauri , Matthew T. Roe , Paramita Saha-Chaudhuri , David Dai , James M. McCabe , Frederic S. Resnic , Hitinder S. Gurm and Robert W. Yeh

Background: Bleeding is associated with poor outcomes after percutaneous coronary intervention (PCI). Although arterial closure devices (ACDs) are widely used in clinical practice, whether they are effective in reducing bleeding complications during transfemoral PCI is uncertain. The objective of this study was to evaluate the effectiveness of ACDs for the prevention of vascular access site complications in patients undergoing transfemoral PCI using an instrumental variable approach.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Intentional Fracture of Maximally Dilated Balloon-Expandable Pulmonary Artery Stents Using Ultra–High-Pressure Balloon Angioplasty

Brian H. Morray, Doff B. McElhinney, Audrey C. Marshall and Diego Porras

Background: Treatment with endovascular stents has become increasingly common for the management of vascular stenosis in congenital heart disease. The use of stents in smaller patients has been tempered by concerns about the potential for stent expansion to accommodate somatic growth. One solution to limited stent diameter is the intentional fracture of maximally dilated stents, which can be accomplished using ultra–high-pressure (UHP) balloons.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Long-Term Clinical Outcomes After Bioresorbable Vascular Scaffold Implantation for the Treatment of Coronary In-Stent Restenosis: A Multicenter Italian Experience

Elisabetta Moscarella , Alfonso Ielasi , Francesco Granata , Sebastian Coscarelli , Eugenio Stabile , Azeem Latib , Bernardo Cortese , Maurizio Tespili , Akihito Tanaka , Claudia Capozzolo , Luigi Caliendo , Antonio Colombo and Attilio Varricchio

Background: Treatment of in-stent restenosis (ISR) is still challenging. In this setting, the use of bioresorbable vascular scaffold (BVS) seems attractive because it allows drug delivery combined with transient vessel scaffolding. We aimed to investigate the long-term results after BVS use in ISR lesions.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Comparison of the Efficacy of Paclitaxel-Eluting Balloon Catheters and Everolimus-Eluting Stents in the Treatment of Coronary In-Stent Restenosis

Leos Pleva, Pavel Kukla, Pavlina Kusnierova, Jana Zapletalova and Ota Hlinomaz

Background: The aim of this prospective randomized noninferiority study was to compare the efficacy of paclitaxel-eluting balloon (PEB) catheters and everolimus-eluting stents (EES) in the treatment of bare metal stent restenosis.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Outcomes Following Primary Percutaneous Coronary Intervention in Patients With Previous Coronary Artery Bypass Surgery

Javaid Iqbal, Chun Shing Kwok, Evangelos Kontopantelis, Mark A. de Belder, Peter F. Ludman, Marilena Giannoudi, Mark Gunning, Azfar Zaman and Mamas A. Mamas

Background: There are limited data on outcomes of patients with previous coronary artery bypass grafting (CABG) presenting with ST-segment–elevation myocardial infarction (STEMI) and undergoing primary percutaneous coronary intervention (PPCI). We report outcomes in patients with STEMI undergoing PPCI with or without previous CABG surgery in a large real-world, all-comer population.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Novel Sirolimus–Coated Balloon Catheter: In Vivo Evaluation in a Porcine Coronary Model

Yvonne Patricia Clever , Daniel Peters , Jorge Calisse , Stephanie Bettink , Madeleine-Caroline Berg , Christian Sperling , Michael Stoever , Bodo Cremers , Bettina Kelsch , Michael Böhm , Ulrich Speck and Bruno Scheller

Background: Limus-eluting stents are dominating coronary interventions, although paclitaxel is the only drug on balloon catheters with proven inhibition of restenosis. Neointimal inhibition by limus-coated balloons has been shown in few animal studies, but data from randomized clinical trials are not available. The aim of the present preclinical studies was to achieve high and persistent sirolimus levels in the vessel wall after administration by a coated balloon.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Quantification of the Effect of Pressure Wire Drift on the Diagnostic Performance of Fractional Flow Reserve, Instantaneous Wave-Free Ratio, and Whole-Cycle Pd/Pa

Christopher M. Cook , Yousif Ahmad , Matthew J. Shun-Shin , Sukhjinder Nijjer , Ricardo Petraco , Rasha Al-Lamee , Jamil Mayet , Darrel P. Francis , Sayan Sen and Justin E. Davies

Background: Small drifts in intracoronary pressure measurements (+-2 mmHg) can affect stenosis categorization using pressure indices. This has not previously been assessed for fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), and whole-cycle distal pressure/proximal pressure (Pd/Pa) indices.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Optical Coherence Tomography–Guided Percutaneous Coronary Intervention in ST-Segment–Elevation Myocardial Infarction: A Prospective Propensity–Matched Cohort of the Thrombectomy Versus Percutaneous Coronary Intervention Alone Trial

Tej N. Sheth , Olli A. Kajander , Shahar Lavi , Ravinay Bhindi , Warren J. Cantor , Asim N. Cheema , Goran Stankovic , Kari Niemelä , Madhu K. Natarajan , Olga Shestakovska , Rachel Tittarelli , Brandi Meeks and Sanjit S. Jolly

Background: Patients undergoing primary percutaneous coronary intervention (PCI) for ST-segment–elevation myocardial infarction are at increased risk for adverse events. It is unclear if image guidance by optical coherence tomography (OCT) can improve outcomes in these patients. We compared OCT-guided versus angiography-guided primary PCI for ST-segment–elevation myocardial infarction among patients in the Thrombectomy Versus PCI Alone (TOTAL) trial.

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Transcatheter Replacement of Stenotic Aortic Valve Normalizes Cardiac–Coronary Interaction by Restoration of Systolic Coronary Flow Dynamics as Assessed by Wave Intensity Analysis

M. Cristina Rolandi, Esther M.A. Wiegerinck, Lorena Casadonte, Ze-Yie Yong, Karel T. Koch, Marije Vis, Jan J. Piek, Jan Baan Jr., Jos A.E. Spaan and Maria Siebes

Background: Aortic valve stenosis (AS) can cause angina despite unobstructed coronary arteries, which may be related to increased compression of the intramural microcirculation, especially at the subendocardium. We assessed coronary wave intensity and phasic flow velocity patterns to unravel changes in cardiac–coronary interaction because of transcatheter aortic valve implantation (TAVI).

01 abril 2016

CIRCULATION: CARDIOVASCULAR INTERVENTIONS. Transcatheter Aortic Valve Implantation in Lower-Risk Patients With Aortic Stenosis: Is It Justified to Be the Preferred Treatment?

Mohammad Abdelghani and Patrick W. Serruys

Transcatheter aortic valve implantation underwent progressive improvements until it became the default therapy for inoperable patients, and a recommended therapy in high-risk operable patients with symptomatic severe aortic stenosis. In the lower-risk patient strata, a currently costly therapy that still has important complications with questionable durability is competing with the established effective and still-improving surgical replacement. This report tries to weigh the clinical evidence, the recent technical improvements, the durability, and the cost-effectiveness claims supporting the adoption of transcatheter aortic valve implantation in intermediate-low risk patients. The importance of appropriate patients’ risk stratification and a more comprehensive approach to estimate that risk are also emphasized in the present report.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.