Higher rates of strokes have been observed in patients with coronavirus disease 2019 (COVID-19), but data regarding the outcomes of COVID-19 patients suffering from acute ischemic stroke due to large vessel occlusion (LVO) are lacking. We report our initial experience in the treatment of acute ischemic stroke with LVO in patients with COVID-19.
Background: Endovascular treatment with mechanical thrombectomy (MT) is beneficial for patients with acute stroke suffering a large-vessel occlusion, although treatment efficacy is highly time-dependent. We hypothesized that interhospital transfer to endovascular-capable centers would result in treatment delays and worse clinical outcomes compared with direct presentation.
Background: Beginning in December 2014, a series of pivotal trials showed that endovascular thrombectomy (EVT) was highly effective, prompting calls to reorganize stroke systems of care. However, there are few data on how these trials influenced the frequency of EVT in clinical practice. We used data from the Get With The Guidelines-Stroke program to determine how the frequency of EVT changed in US practice.
Background: Cerebral hypoperfusion has previously been associated with mild cognitive impairment and dementia in various cross-sectional studies, but whether hypoperfusion precedes neurodegeneration is unknown. We prospectively determined the association of cerebral perfusion with subsequent cognitive decline and development of dementia.
BACKGROUND AND PURPOSE: Although endovascular treatment has become a standard therapy in patients with acute stroke, the benefit for very old patients remains uncertain. The purpose of this study was the evaluation of procedural and outcome data of patients >=90 years undergoing endovascular stroke treatment.
BACKGROUND AND PURPOSE: Endovascular treatment of intracranial aneurysms is associated with the risk of thromboembolic ischemic complications. Many of these events are asymptomatic and identified only on diffusion-weighted imaging. We performed a systematic review and meta-analysis to study the incidence of DWI positive for thromboembolic events following endovascular treatment of intracranial aneurysms.
BACKGROUND AND PURPOSE: Rabbit elastase-induced saccular aneurysms have been commonly used for preclinical testing of endovascular devices, including flow diverters. However, all tested devices have been shown to be capable of aneurysm occlusion with this model. We aimed to create a more challenging model to test and discriminate among neurovascular devices of varying efficacies.
BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device has emerged as an attractive treatment for cerebral aneurysms. Processes involved in aneurysm occlusion include changes in intra-aneurysmal hemodynamics and endothelialization of the device. Here, we call attention to a radiographic sign not previously reported that is detected in incompletely occluded aneurysms after treatment with the Pipeline Embolization Device at angiographic follow-up and referred to as the “collar sign.”
BACKGROUND AND PURPOSE: Although core needle biopsy was introduced as a diagnostic alternative to fine-needle aspiration, the utility and safety of core needle biopsy for thyroid nodules in a large population has yet to be studied comprehensively. We evaluate core needle biopsy yields on a large-scale basis to investigate its potential in the preliminary diagnosis of thyroid nodules.
BACKGROUND AND PURPOSE: Inadvertent intrafacet injection can occur during interlaminar epidural steroid injection, resulting in a false-positive loss of resistance and nontarget injection of medication. The purpose of this investigation was to compare the observed rates of this phenomenon during lumbar interlaminar epidural steroid injection performed by using conventional fluoroscopic and CT fluoroscopic guidance.
BACKGROUND AND PURPOSE: Spinal arteriovenous shunts below the conus constitute 3 types of lesions, which have previously been mainly described in case reports, given their rarity, and are sometimes misdiagnosed. The purpose of this study was to describe the features of each type and compare these types as to epidemiologic features, clinical and radiologic presentations, treatment, and outcomes in a consecutive series of 48 cases.
BACKGROUND AND PURPOSE: The adverse effects of general anesthesia in stroke thrombectomy have been attributed to intraprocedural hypotension, yet optimal hemodynamic targets remain elusive. Identifying hemodynamic thresholds from patients without exposure to general anesthesia may help separate the effect of hypotension from the effect of anesthesia in thrombectomy outcomes. Therefore, we investigated which hemodynamic parameters and targets best correlate with outcome in patients treated under sedation with monitored anesthesia care.
BACKGROUND AND PURPOSE: The novel technique of 4D CTA for dynamic assessment of the intracranial vessels has a greater radiation burden than conventional CTA. Previous descriptions of the technique used a fixed-duration exposure protocol. This study examines the potential for dose reduction by individualizing exposure time to patient physiology by the use of time-enhancement curve techniques as previously applied in CT angiography and venography.
BACKGROUND AND PURPOSE: Endovascular treatment with the flow-disrupter Woven EndoBridge aneurysm embolization system (WEB) is an innovative treatment for wide-neck bifurcation aneurysms. Prospective, multicenter studies have shown the high safety of this technique. Stability of aneurysm occlusion in long-term follow-up has been rarely studied. Moreover the “compression” phenomenon has been reported and seems to be associated with poor anatomic results. This prospective, single-center series analyzes the safety and efficacy of the WEB device in long-term follow-up in relation to WEB shape modification.
BACKGROUND AND PURPOSE: Intrasaccular flow diverters are increasingly being used in the treatment of wide-neck and bifurcation aneurysms. We performed a systematic review and meta-analysis of existing literature on the Woven EndoBridge device in the treatment of intracranial aneurysms.
Cookies Sociales
Son esos botones que permiten compartir el contenido del sitio web en sus redes sociales (Facebook, Twitter y Linkedin, previo tu consentimiento y login) a través de sistemas totalmente gestionados por dichas redes sociales, así como los recursos (pej. videos) y material que se encuentra en nuestra web, y que de igual manera se presta y gestiona completamente por un tercero.
Si no acepta estas cookies, no podrá compartir nuestro contenido a través de los botones, y en su caso, no podrás visualizar el contenido de terceros que hayamos incrustado en el sitio.
No las utilizamos