Foros de Conocimiento
medtronic PRODUCTOS
boston_scientific PRODUCTOS
TERUMO PRODUCTOS
Biotronik PRODUCTOS
Sirtex PRODUCTOS
Striker Neurovascular PRODUCTOS
BIOSENSORS PRODUCTOS

ESTUDIOS


11 noviembre 2014

STROKE. Clinical Sciences. Increased Risk for Intracranial Arterial Stenosis in Subjects With Coronary Artery Calcification

Hyung-Geun Oh, MD, PhD; Pil-Wook Chung, MD, PhD; Eun-Jung Rhee, MD, PhD

Background and Purpose: Intracranial arterial stenosis (ICAS) is considered an important cause of stroke in Asians. Coronary artery calcification (CAC) is a surrogate marker for subclinical atherosclerosis. We aimed to analyze the association of ICAS assessed by transcranial Doppler ultrasonography and CAC in middle-aged Korean population.

21 octubre 2014

STROKE. Clinical Sciences. Mechanisms of Unexplained Neurological Deterioration After Intravenous Thrombolysis

Marie Tisserand, MD*; Pierre Seners, MSc*; Guillaume Turc, MD; Laurence Legrand, MD; Marc-Antoine Labeyrie, MD; Sylvain Charron, PhD; Jean-François Méder, PhD; Jean-Louis Mas, MD; Catherine Oppenheim, PhD†; Jean-Claude Baron, ScD†

Background and Purpose: Unstable clinical course characterizes the first 24 hours after thrombolysis for anterior circulation stroke, including early neurological deterioration (END), a secondary complication consistently predictive of poor outcome. Apart from straightforward causes, such as intracerebral hemorrhage and malignant edema, the mechanism of END remains unclear in the majority of cases (ENDunexplained). Based on the core/penumbra model, we tested the hypothesis that ENDunexplained is caused by infarct growth beyond the initial penumbra and assessed the associated vascular patterns.

07 octubre 2014

STROKE. Clinical Sciences. Application of Single-Stage Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations >10 cm3

Shunya Hanakita, MD; Tomoyuki Koga, MD, PhD; Masahiro Shin, MD, PhD; Hiroshi Igaki, MD, PhD; Nobuhito Saito, MD, PhD

Background and Purpose: Stereotactic radiosurgery (SRS) is a safe and effective treatment for small arteriovenous malformations (AVMs), the use of this modality for the treatment of large AVMs is still controversial, although it has been used in difficult cases. The aim of this study was to evaluate the treatment outcomes of patients who underwent single-stage SRS for large AVMs and to discuss the role of SRS in the treatment of these challenging lesions.

01 noviembre 2015

DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. Single-stage endovascular treatment in patients with severe extracranial large vessel stenosis and concomitant ipsilateral unruptured intracranial aneurysm

Emre Kaçar 1 , Ömer Fatih Nas 2 , Cüneyt Erdoğan 2 , Bahattin Hakyemez 2

PURPOSE: We aimed to evaluate the safety and effectiveness of single-stage endovascular treatment in patients with severe extracranial large vessel stenosis and concomitant ipsilateral unruptured intracranial aneurysm.

09 julio 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Single-Layer WEBs: Intrasaccular Flow Disrupters for Aneurysm Treatment—Feasibility Results from a European Study

J. Caroff, C. Mihalea, J. Klisch, C. Strasilla, A. Berlis, T. Patankar, W. Weber, D. Behme, E.A. Jacobsen, T. Liebig, S. Prothmann, C. Cognard, T. Finkenzeller, J. Moret and L. Spelle

BACKGROUND AND PURPOSE: The safety and efficiency of the dual-layer Woven EndoBridge (WEB) device has already been published. However, this international multicenter study sought to evaluate the safety of single-layer devices, which are the newest generation of the WEB intrasaccular flow-disrupter family. They have been designed to offer smaller-sized devices with a lower profile to optimize navigability and delivery, which may, in turn, broaden their range of use.

28 mayo 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Stent-Assisted Coiling of Wide-Neck Intracranial Aneurysms Using Low-Profile LEO Baby Stents: Initial and Midterm Results

K. Aydin, A. Arat, S. Sencer, M. Barburoglu and S. Men

BACKGROUND AND PURPOSE: Low-profile self-expandable stents were recently introduced for the treatment of wide-neck intracranial aneurysms. This study investigated the initial and midterm clinical and angiographic results of LEO Baby stent–assisted coiling in the treatment of wide-neck intracranial aneurysms.

18 junio 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Hemodynamic Differences in Intracranial Aneurysms before and after Rupture

B.M.W. Cornelissen, J.J. Schneiders, W.V. Potters, R. van den Berg, B.K. Velthuis, G.J.E. Rinkel, C.H. Slump, E. VanBavel, C.B.L.M. Majoie and H.A. Marquering

BACKGROUND AND PURPOSE: Rupture risk of intracranial aneurysms may depend on hemodynamic characteristics. This has been assessed by comparing hemodynamic data of ruptured and unruptured aneurysms. However, aneurysm geometry may change before, during, or just after rupture; this difference causes potential changes in hemodynamics. We assessed changes in hemodynamics in a series of intracranial aneurysms, by using 3D imaging before and after rupture.

25 junio 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke: A Diagnostic Performance Study

E.J. Smit, E.-j. Vonken, F.J.A. Meijer, J.W. Dankbaar, A.D. Horsch, B. van Ginneken, B. Velthuis, I. van der Schaaf and M. Prokop

BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the diagnostic accuracy of timing-invariant CTA for detecting intracranial artery occlusion in acute ischemic stroke, to examine whether standard CTA can be omitted.

06 agosto 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-Labeling in Healthy Volunteers

K. Ambarki, A. Wåhlin, L. Zarrinkoob, R. Wirestam, J. Petr, J. Malm and A. Eklund

BACKGROUND AND PURPOSE: The arterial spin-labeling method for CBF assessment is widely available, but its accuracy is not fully established. We investigated the accuracy of a whole-brain arterial spin-labeling technique for assessing the mean parenchymal CBF and the effect of aging in healthy volunteers. Phase-contrast MR imaging was used as the reference method.

30 abril 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Intracranial Aneurysms: Wall Motion Analysis for Prediction of Rupture

A.E. Vanrossomme, O.F. Eker, J.-P. Thiran, G.P. Courbebaisse and K. Zouaoui Boudjeltia

SUMMARY: Intracranial aneurysms are a common pathologic condition with a potential severe complication: rupture. Effective treatment options exist, neurosurgical clipping and endovascular techniques, but guidelines for treatment are unclear and focus mainly on patient age, aneurysm size, and localization. New criteria to define the risk of rupture are needed to refine these guidelines. One potential candidate is aneurysm wall motion, known to be associated with rupture but difficult to detect and quantify. We review what is known about the association between aneurysm wall motion and rupture, which structural changes may explain wall motion patterns, and available imaging techniques able to analyze wall motion.

30 junio 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Wall Mechanical Properties and Hemodynamics of Unruptured Intracranial Aneurysms

J.R. Cebral, X. Duan, B.J. Chung, C. Putman, K. Aziz and A.M. Robertson

BACKGROUND AND PURPOSE: Aneurysm progression and rupture is thought to be governed by progressive degradation and weakening of the wall in response to abnormal hemodynamics. Our goal was to investigate the relationship between the intra-aneurysmal hemodynamic conditions and wall mechanical properties in human aneurysms.

06 agosto 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Evolution of Flow-Diverter Endothelialization and Thrombus Organization in Giant Fusiform Aneurysms after Flow Diversion: A Histopathologic Study

I. Szikora, E. Turányi and M. Marosfoi

BACKGROUND AND PURPOSE: Treatment of giant fusiform aneurysms with flow diverters has been associated with a relatively high rate of complications. Our goal was to study the evolution of flow-diverter endothelialization and thrombus organization at different time points after flow-diverter treatment in giant fusiform aneurysms to better understand reasons for flow-diverter thrombosis and delayed aneurysm ruptures.

02 julio 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Intrasaccular Flow Disruption in Acutely Ruptured Aneurysms: A Multicenter Retrospective Review of the Use of the WEB

T. Liebig, C. Kabbasch, C. Strasilla, A. Berlis, W. Weber, L. Pierot, T. Patankar, X. Barreau, J. Dervin, A. Kuršumović, S. Rath, B. Lubicz and J. Klisch

BACKGROUND AND PURPOSE: Use of the WEB intra-aneurysmal flow-disruption device in unruptured wide-neck bifurcation aneurysms has proven safety and efficacy. However, ruptured aneurysms are underrepresented in existing studies. This retrospective multicenter study describes the use of the WEB in patients with a ruptured intracranial aneurysm.

23 julio 2015

AMERICAN JOURNAL OF NEURORADIOLOGY. Artery of the Superior Orbital Fissure: An Undescribed Branch from the Pterygopalatine Segment of the Maxillary Artery to the Orbital Apex Connecting with the Anteromedial Branch of the Inferolateral Trunk

H. Kiyosue, S. Tanoue, N. Hongo, Y. Sagara and H. Mori

BACKGROUND AND PURPOSE: Some branches of the internal maxillary artery have anastomoses with the inferolateral trunk that are important as intracranial-extracranial collateral pathways and as dangerous anastomoses for transarterial embolization of these branches. We present here an undescribed branch potentially anastomosing with the anteromedial branch of the inferolateral trunk, which is provisionally named the artery of the superior orbital fissure, defined as an arterial branch from the pterygopalatine segment of the maxillary artery to the orbital apex at the superior orbital fissure.

Utilizamos cookies propias para el correcto funcionamiento del sitio web y mejorar nuestros servicios. Pulse el botón Aceptar todas para aceptar su uso. Puede cambiar la configuración u obtener más información en nuestra Política de cookies o pulsando Modificar configuración.